Stack effect in window units of high-rise buildings. A Review

Строительные конструкции, здания и сооружения
Авторы:
Аннотация:

This review article provides a comprehensive analysis of the stack effect's influence on the air permeability of window structures, infiltration heat loss, and acoustic manifestations of air leaks in high-rise buildings. The aim of the study is to clarify the physical mechanism underlying the relationship between temperature and wind effects, pressure differences, window unit design features, and actual airflow through leaks. Methodology: An analytical review of scientific publications (publications since 2020, Scopus database) on the stack effect, air permeability of building envelopes, natural infiltration, indoor air quality, and acoustic air leak diagnostics was conducted. Engineering calculations were performed to determine the stack effect pressure on a window unit, airflow through leaks, and airflow velocity in localized slot channels. The combined effects of temperature and wind pressure on the performance of window structures were analyzed. Results and Discussion: It has been established that the actual air permeability of window units depends not only on the regulatory class but also on the pressure drop, temperature and wind conditions, the area of the structure, and ventilation operation. It has been shown that areas of hinges, rebate joints, drainage holes, and damage to the sealing contour can form the main leakage channels even with high overall window airtightness. It has been established that reducing the area of localized leaks increases the airflow velocity through the remaining channels, contributing to the development of vortex flows and aerodynamic noise. It has been shown that high window airtightness reduces uncontrolled infiltration and associated heat loss. Still, in the absence of organized airflow, it can lead to insufficient air exchange and increased concentrations of СО2, moisture, and other pollutants. An additional factor is the spatial heterogeneity of wind pressure: localized zones of vacuum and increased pressure pulsations form in the corner, lateral, and leeward areas of the façade, which can increase air leakage and acoustic discomfort. Conclusion: Reducing the negative consequences of the stack effect requires the comprehensive use of sealed window structures, improved sealing contours, localized sealing of components, and the installation of controlled airflow and balanced ventilation systems. The results obtained can be used to evaluate the thermal, aerodynamic, and acoustic performance of window structures in high-rise buildings.

Финансовые условия:

This research was funded by the Ministry of Science and Higher Education of the Russian Federation within the framework of the state assignment \u2116 075-03-2026-218 dated 16 January 2026, Additional agreement \u2116 075-03-2026-218/7 dated 4 June 2026, FSEG-2025-0008.

  • Список литературы

    1.        Wang, R., Wan, M., Jiang, H., Wu, X., Zhang, P., & Lu, S. (2026). Building Energy Thermal Resilience under Compound Long-and-Short-Term Climate Disturbances: Impact Mechanisms, Quantitative Evaluation, and Energy Storage Enhancement. Energy Use, 2(2), 100059–1. https://doi.org/10.59717/IPJ.ENERGY-USE.2026.100059

    2.        Campagna, L. M., & Fiorito, F. (2022). On the Impact of Climate Change on Building Energy Consumptions: A Meta-Analysis. Energies, 15(1), 354. https://doi.org/10.3390/EN15010354

    3.        Chen, Y., Ren, Z., Peng, Z., Yang, J., Chen, Z., & Deng, Z. (2023). Impacts of climate change and building energy efficiency improvement on city-scale building energy consumption. Journal of Building Engineering, 78, 107646. https://doi.org/10.1016/J.JOBE.2023.107646

    4.        Kutty, N. A., Barakat, D., Darsaleh, A. O., & Kim, Y. K. (2023). A Systematic Review of Climate Change Implications on Building Energy Consumption: Impacts and Adaptation Measures in Hot Urban Desert Climates. Buildings, 14(1), 13. https://doi.org/10.3390/BUILDINGS14010013

    5.        Zheng, H., Gao, G., Zhong, X., & Zhao, L. (2022). Monitoring and diagnostics of buildings' heat loss based on 3D IR model of multiple buildings. Energy and Buildings, 259, 111889. https://doi.org/10.1016/J.ENBUILD.2022.111889

    6.        Kim, S., Seo, J., Jeong, H., & Kim, J. (2022). In situ measurement of the heat loss coefficient of thermal bridges in a building envelope. Energy and Buildings, 256, 111627. https://doi.org/10.1016/J.ENBUILD.2021.111627

    7.        Younes, C., Shdid, C. A., & Bitsuamlak, G. (2012). Air infiltration through building envelopes: A review. Journal of Building Physics, 35(3), 267–302. https://doi.org/10.1177/1744259111423085

    8.        Hong, G., & Kim, B. S. (2016). Field measurements of infiltration rate in high rise residential buildings using the constant concentration method. Building and Environment, 97, 48–54. https://doi.org/10.1016/J.BUILDENV.2015.11.027

    9.        Shi, S., Chen, C., & Zhao, B. (2015). Air infiltration rate distributions of residences in Beijing. Building and Environment, 92, 528–537. https://doi.org/10.1016/J.BUILDENV.2015.05.027

    10.      Mahmoodzadeh, M., Gretka, V., Wong, S., Froese, T., & Mukhopadhyaya, P. (2020). Evaluating Patterns of Building Envelope Air Leakage with Infrared Thermography. Energies, 13(14), 3545. https://doi.org/10.3390/EN13143545

    11.      Schiricke, B., Diel, M., & Kölsch, B. (2024). Field Testing of an Acoustic Method for Locating Air Leakages in Building Envelopes. Buildings, 14(4), 1159. https://doi.org/10.3390/BUILDINGS14041159

    12.      Lim, S., Choi, S. J., Jing, J., & Jo, J. H. (2025). A Methodology for Deriving Conversion Coefficients of Natural Infiltration Using Airtightness Data. Energies, 18(23), 6301. https://doi.org/10.3390/EN18236301

    13.      Hassouneh, K., Alshboul, A., & Al-Salaymeh, A. (2012). Influence of infiltration on the energy losses in residential buildings in Amman. Sustainable Cities and Society, 5(1), 2–7. https://doi.org/10.1016/J.SCS.2012.09.004

    14.      Pinto, M., Viegas, J., & de Freitas, V. P. (2011). Air permeability measurements of dwellings and building components in Portugal. Building and Environment, 46(12), 2480–2489. https://doi.org/10.1016/J.BUILDENV.2011.06.009

    15.      BSI-075: How Do Buildings Stack Up? https://buildingscience.com/documents/insights/bsi-075-how-do-buildings-stack-up

    16.      Denisikhina, M. D., & Samoletov, M. V. (n.d.). The Stack Effect: from the Driving Force of Natural Ventilation to the Headache of High-Rise Buildings. https://www.abok.ru/for_spec/articles.php?nid=8592

    17.      Hwang, T., Hwang, M. K., & Kim, J. (2025). Reduction Characteristics of Stack-Effect Problems According to Applying Local Countermeasures by Pressure Distribution Measurement in Buildings. Buildings, 15(24), 4453. https://doi.org/10.3390/BUILDINGS15244453

    18.      Jing, J. J., Ji, K. H., Yoon, S., & Jo, J. H. (2024). A novel method for evaluating stack pressure in real high-rise buildings: Optimization of measurement points. Building and Environment, 259. https://doi.org/10.1016/J.BUILDENV.2024.111661

    19.      Yousefi, M. M. (2025). CFD simulation and field validation of stack effect in elevator shafts and the effects of airflow on elevator door operation. Theses. https://repository.rit.edu/theses/12370

    20.      Zhang, X., Ma, Y., Wang, Q., Zhang, H., & Zhao, S. (2023). Research on the thermal pressure of elevator shaft in high-rise residential building under different cooling conditions based on computer simulation. Proc. SPIE 12639, Third International Conference on Mechanical Design and Simulation (MDS 2023), 12639, 250. https://doi.org/10.1117/12.2681813

    21.      Rubino, C., Liuzzi, S., & Martellotta, F. (2026). Assessing airflow performance of ventilated acoustic metamaterials: a methodology to foster comparability of results. Building and Environment, 288, 114001. https://doi.org/10.1016/J.BUILDENV.2025.114001

    22.      Park, S., Park, S., & Song, D. (2026). Guidelines for predicting airtightness in residential buildings under climatic pressure conditions. Energy and Built Environment, 7(2), 267–277. https://doi.org/10.1016/J.ENBENV.2024.11.002

    23.      Hu, J., Liu, Z., Ma, G., Zhang, G., & Ai, Z. (2023). Air infiltration and related building energy consumption: A case study of office buildings in Changsha, China. Journal of Building Engineering, 74, 106859. https://doi.org/10.1016/J.JOBE.2023.106859

    24.      Vera Alves, Romero Rincón, M., Tudela, J., & Martínez Beltrán, P. (2026). Comparison of models for estimating air infiltration in dwellings and their impact on heating demand. Energy Efficiency, 19(1), 10-. https://doi.org/10.1007/S12053-026-10413-W

    25.      Lozinsky, C. H., Casquero-Modrego, N., Walker, I. S., Less, B. D., Graessle, Q. P., & Sohn, M. D. (2026). The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings. International Journal of Ventilation, 25(2), 204–225. https://doi.org/10.1080/14733315.2025.2550854

    26.      Lee, D. S., Ji, K. H., Jing, J., & Jo, J. H. (2022). Experimental study on elevator door reopening problems caused by stack induced pressure differences across the elevator door in buildings. Building and Environment, 221, 109271. https://doi.org/10.1016/J.BUILDENV.2022.109271

    27.      Xie, X. F., & Yang, Y. (2020). Numerical investigation on the stack effect of a general high-rise building model. Engineering Mechanics, 37(3), 217–227. https://doi.org/10.6052/J.ISSN.1000-4750.2019.05.0251

    28.      Huang, K., Yu, M., Liu, X., & Wang, R. (2024). The mathematical model of kitchen smoke exhaust system in high-rise residential buildings considering the Influence of Stack effect. Energy and Built Environment, 5(4), 580–591. https://doi.org/10.1016/J.ENBENV.2023.04.007

    29.      See, S. W., & Balasubramanian, R. (2008). Chemical characteristics of fine particles emitted from different gas cooking methods. Atmospheric Environment, 42(39), 8852–8862. https://doi.org/10.1016/J.ATMOSENV.2008.09.011

    30.      Hang, J., Li, Y., Sandberg, M., Buccolieri, R., & Di Sabatino, S. (2012). The influence of building height variability on pollutant dispersion and pedestrian ventilation in idealized high-rise urban areas. Building and Environment, 56, 346–360. https://doi.org/10.1016/J.BUILDENV.2012.03.023

    31.      Lim, T., Cho, J., & Kim, B. S. (2010). The predictions of infection risk of indoor airborne transmission of diseases in high-rise hospitals: Tracer gas simulation. Energy and Buildings, 42(8), 1172–1181. https://doi.org/10.1016/J.ENBUILD.2010.02.008

    32.      Miller, R. S., & Beasley, D. (2009). On stairwell and elevator shaft pressurization for smoke control in tall buildings. Building and Environment, 44(6), 1306–1317. https://doi.org/10.1016/J.BUILDENV.2008.09.015

    33.      Abdullah, N. S., Hanapi, N. L., Apet, R. A. A., Azmy, M. S., Jalil, N. A. A., & Tatriwartami, M. (2025). Numerical Simulation: Smoke Movement at Stairwell of High-rise Buildings. Journal of Design and Built Environment, 2025(Special Issue 7), 123–141. https://doi.org/10.22452/JDBE.SPVII.9

    34.      Frikel, M. D., Paskhina, D. A., Anosova, E. B., & Sandalov, V. M. (2023). Application of the PyroSim software product to assess the dynamics of distribution of hazardous factors using a zone model. Advances in Chemistry and Chemical Engineering (in Rus), 37(10 (272)), 90–95. https://cyberleninka.ru/article/n/primenenie-programmnogo-produkta-pyrosim-dlya-otsenki-dinamiki-rasprostraneniya-opasnyh-faktorov-pri-ispolzovanii-zonnoy-modeli

    35.      Ene, I. C., Iordache, V., & Anghel, I. (2024). The Impact of an Office Fire Combined with the Stack Effect in a Multi-Story Building. Applied Sciences, 14(24), 11659. https://doi.org/10.3390/APP142411659

    36.      Reichman, R., & Dubowski, Y. (2021). Gaseous pollutant transport from an underground parking garage in a Mediterranean multi-story building—Effect of temporal resolution under varying weather conditions. Building Simulation, 14(5), 1511–1523. https://doi.org/10.1007/S12273-020-0757-4

    37.      Klote, J. H., & Milke, J. A. (n.d.). Principles of Smoke Management. https://firedoc.nist.gov/article/i3gzXYQBWEcjUZEYKAmN

    38.      Mona, Azarbayjani, Jigisha, & Mehta. (n.d.). Climatic Based Consideration of Double Skin Façade System: Comparative Analysis of Energy Performance of a Double Skin Façade Building in Boston. https://doi.org/10.5555/2339453.2339461

    39.      Black, W. Z. (2010). COSMO—Software for designing smoke control systems in high-rise buildings. Fire Safety Journal, 45(6–8), 337–348. https://doi.org/10.1016/J.FIRESAF.2010.07.001

    40.      Bellido, C., Quiroz, A., Panizo, A., & Torero, J. L. (2009). Performance assessment of pressurized stairs in high rise buildings. Fire Technology, 45(2), 189–200. https://doi.org/10.1007/S10694-008-0078-0/TABLES/3

    41.      Xu, H., Su, L., Lou, W., & Shan, H. (2024). Combined Effects of Thermal Buoyancy, Wind Action, and State of the First-Floor Lobby Entrance on the Pressure Difference in a High-Rise Building. Energies, 17(9), 2117. https://doi.org/10.3390/EN17092117

    42.      Yang, Y., Hou, R., & Xie, C. (2024). Full-scale experimental simulation of the stack effect pressure acting on an elevator door system in a high-rise building. Building and Environment, 256, 111443. https://doi.org/10.1016/J.BUILDENV.2024.111443

    43.      Li, Y., Zhu, N., & Hou, Y. (2023). Multi-Criteria Decision-Making of Countermeasure Combination for Mitigating the Stack Effect in High-Rise Office Building. Buildings,13(3), 653. https://doi.org/10.3390/BUILDINGS13030653

    44.      Yu, J. yeon, Song, K. dong, & Cho, D. woo. (2017). Resolving Stack Effect Problems in a High-Rise Office Building by Mechanical Pressurization. Sustainability, 9(10), 1731. https://doi.org/10.3390/SU9101731

    45.      Park, S. Y., Choi, S. J., Lee, D. S., & Jo, J. H. (2025). Assessing stack-induced infiltration loads by predicting neutral pressure levels in high-rise buildings. Building Simulation, 18(5), 999–1017. https://doi.org/10.1007/S12273-025-1255-5

    46.      GOST 23166-2024 Window and balcony blocks. General specifications. https://docs.cntd.ru/document/1305402755

    47.      ISO 9972-2015 Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method. https://docs.cntd.ru/document/431977007

    48.      ASTM E283 Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. (n.d.). West Conshohocken, PA: ASTM International. https://doi.org/10.1520/E0283_E0283M-26

    49.      DIN EN 12207-2017 Windows and doors - Air permeability – Classification. https://docs.cntd.ru/document/440169302

    50.      New Windows Still Drafty? The 4 Hidden Reasons Your "Thermal Break" Aluminum Windows Are Failing. https://www.gdaaluminiumprofile.com/news/what-window-dealers-won-t-tell-you-why-your-thermal-break-aluminum-windows-start-leaking-air-in-2-years-349535.html

    51.      Ustinov, V. V. (n.d.). Determining the Minimum Outside Air Flowrate in Design of Ventilation Systems. https://www.abok.ru/for_spec/articles.php?nid=6507

    52.      SP 60.13330.2020 Heating, ventilation and air conditioning. https://docs.cntd.ru/document/573697256

    53.      ASHRAE STD 62.1-2020 Ventilation for Acceptable Indoor Air Quality. https://docs.cntd.ru/document/565106304

    54.      Kempton, L., Daly, D., Kokogiannakis, G., & Dewsbury, M. (2022). A rapid review of the impact of increasing airtightness on indoor air quality. Journal of Building Engineering, 57, 104798. https://doi.org/10.1016/J.JOBE.2022.104798

    55.      Roy Choudhury, A., Singh, N., Chinthala, S., Lalwani, J., Sri Kalyana Rama, J., Chandana, N., … Akhbari, A. (2025). Environmental health hazards attributed to deteriorated indoor air quality caused by inferior construction practices. Environmental Science: Atmospheres, 5(9), 941–961. https://doi.org/10.1039/D5EA00027K

    56.      Alhindawi, I., Fernandes, J. M., Sood, D., O'Donnell, J., & Byrne, M. A. (2026). A longitudinal study of CO2 and air exchange rate variations in naturally ventilated airtight energy-efficient dwellings. Journal of Building Engineering, 119. https://doi.org/10.1016/J.JOBE.2026.115257

    57.      Scrosati, C., Bianco, F., Depalma, M., Belussi, L., Strini, A., Schiavi, L., … Garai, M. (2025). Preliminary evaluation of ventilation and acoustics insulation of partially open windows for the PRIN – METAWAVE project. 54th International Congress and Exposition on Noise Control Engineering, INTERNOISE 2025, 1, 3158–3164. https://doi.org/10.3397/IN_2025_1090359

    58.      Elsaei, A., Machimbarrena, M., Meiss, A., Poza-Casado, I., & Padilla-Marcos, M. A. (2025). A multi-stage analysis of air leakage and acoustic performance on a full-scale test chamber. Journal of Building Engineering, 114, 114301. https://doi.org/10.1016/J.JOBE.2025.114301

    59.      Chum, S., Lozinsky, C. H., Andargie, M. S., & Touchie, M. F. (2023). Empirical investigation of interzonal air leakage and airborne sound transmission correlation in multi-unit residential buildings. Building and Environment, 239, 110345. https://doi.org/10.1016/J.BUILDENV.2023.110345

    60.      SP 20.13330.2016 Loads and actions. https://docs.cntd.ru/document/456044318

    61.      Li, J., & Li, Z. (2024). Acoustic wind tunnel experimental study of aerodynamic noise distribution in high-rise buildings. Journal of Building Engineering, 91, 109621. https://doi.org/10.1016/J.JOBE.2024.109621

    62.      Tominaga, Y., Mochida, A., Yoshie, R., Kataoka, H., Nozu, T., Yoshikawa, M., & Shirasawa, T. (2008). AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96(10–11), 1749–1761. https://doi.org/10.1016/J.JWEIA.2008.02.058

    63.      Wijesooriya, K., Mohotti, D., Lee, C. K., & Mendis, P. (2023). A technical review of computational fluid dynamics (CFD) applications on wind design of tall buildings and structures: Past, present and future. Journal of Building Engineering, 74, 106828. https://doi.org/10.1016/J.JOBE.2023.106828

    64.      Estrado, E., Turrin, M., & Eigenraam, P. (2023). Optimization of complex-geometry high-rise buildings based on wind load analysis. Simulation, 99(11), 1133–1146. https://doi.org/10.1177/00375497221109577;WGROUP:STRING:PUBLICATION

    65.      Man, X., Lu, Y., Li, G., Wang, Y., & Liu, J. (2020). A study on the stack effect of a super high-rise residential building in a severe cold region in China. Indoor and Built Environment, 29(2), 255–269. https://doi.org/10.1177/1420326X19856045

    66.      Jing, J., Lee, D. S., & Jo, J. H. (2026). Stack effect in high-rise buildings: A comprehensive review on theoretical mechanisms, impacts, and evaluation methods. Building and Environment, 288, 113971. https://doi.org/10.1016/J.BUILDENV.2025.113971

    67.      Kolsch, B., Walker, I., Delp, W., Schiricke, B., & Hoffschmidt, B. (2022, May 1). Comparison of Airflow and Acoustic Measurements for Evaluation of Building Air Leakage Paths in a Laboratory Test Apparatus. https://escholarship.org/uc/item/6r69f93b

    68.      Moed, H. F., Bar-Ilan, J., & Halevi, G. (2016). A new methodology for comparing Google Scholar and Scopus. Journal of Informetrics, 10(2), 533–551. https://doi.org/10.1016/J.JOI.2016.04.017

    69.      Montoya, F. G., Alcayde, A., Baños, R., & Manzano-Agugliaro, F. (2018). A fast method for identifying worldwide scientific collaborations using the Scopus database. Telematics and Informatics, 35(1), 168–185. https://doi.org/10.1016/J.TELE.2017.10.010

    70.      GOST R 59972-2021 "Ventilation and air conditioning systems of public buildings. Technical requirements. https://docs.cntd.ru/document/1200182524

    71.      Shi, X., Li, Y., Long, T., Zhao, N., Liu, S., & Li, T. (2023). Buoyancy-driven natural ventilation performance of a multi-story building with vertical shaft designed by using dimensionless design approach. Sustainable Cities and Society, 99, 104997. https://doi.org/10.1016/J.SCS.2023.104997

    72.      Jo, J. H., Lim, H., Yoon, S., & Jing, J. (2026). Ten questions concerning stack effect issues in high-rise buildings. Building and Environment, 115049. https://doi.org/10.1016/J.BUILDENV.2026.115049

    73.      Yoon, S., Song, D., Kim, J., Kim, J., Lim, H., & Koo, J. (2020). Identifying stack-driven indoor environmental problems and associated pressure difference in high-rise residential buildings: Airflow noise and draft. Building and Environment, 168, 106483. https://doi.org/10.1016/J.BUILDENV.2019.106483

    74.      Schuldenfrei, E., Tang, X., Deng, X., Wang, Q., Lin, Z., & Huang, J. (2026). Multi-zone modeling of airflow in a free running building floor: Possible implications for disease transmission. Building Simulation, 19(3), 587–603. https://doi.org/10.1007/S12273-026-1417-0

    75.      Liu, M., Jiang, X., Sun, J., Wu, L., Zhang, X., Hua, L., & Yang, W. (2026). Comprehensive numerical assessment of stack effect mitigation in high-rise buildings: impacts of architectural, mechanical, and climatic factors. Science and Technology for the Built Environment. https://doi.org/10.1080/23744731.2026.2643576

    76.      Rolfsmeier, S., Mairinger, E., Neubig, J., & Gayer, T. (2025). Measuring Airtightness of High-Rise Buildings (Lessons Learned). Buildings, 15(5), 724. https://doi.org/10.3390/BUILDINGS15050724

    77.      Pereira, P. F., & Ramos, N. M. M. (2021). The impact of mechanical ventilation operation strategies on indoor CO2 concentration and air exchange rates in residential buildings. Indoor and Built Environment, 30(9), 1516–1530. https://doi.org/10.1177/1420326X20960767;WGROUP:STRING:PUBLICATION

    78.      Wallner, P., Munoz, U., Tappler, P., Wanka, A., Kundi, M., Shelton, J. F., & Hutter, H. P. (2015). Indoor Environmental Quality in Mechanically Ventilated, Energy-Efficient Buildings vs. Conventional Buildings. International Journal of Environmental Research and Public Health, 12(11), 14132–14147. https://doi.org/10.3390/IJERPH121114132

    79.      Alhindawi, I., McGrath, J. A., Sood, D., O'Donnell, J., & Byrne, M. A. (2025). A seasonal assessment of indoor air quality and thermal performance in naturally ventilated airtight energy-efficient dwellings. Building and Environment, 276. https://doi.org/10.1016/J.BUILDENV.2025.112862

    80.      Zhao, H., Martin, E., Khan, T., Chasar, D., Sonne, J., Withers, C. R., … Singer, B. C. (2025). Mechanical ventilation and indoor air quality in recently constructed homes in the humid climate of the Southeast U.S. Indoor Environments, 2(4), 100121. https://doi.org/10.1016/J.INDENV.2025.100121

    81.      Palcikovskis, A., Lebedeva, K., Zemitis, J., Borodinecs, A., & Prozuments, A. (2025). Analysis of Window Trickle Vents at Various Pressure Differences. Sustainability, 17(20), 9304. https://doi.org/10.3390/SU17209304

    82.      Aksenov, I., & Konstantinov, A. (2024). Window air permeability calculation methodology with regard to temperature loading. E3S Web of Conferences, 535. https://doi.org/10.1051/E3SCONF/202453501001

    83.      Van Linden, S., & Van Den Bossche, N. (2020). Airtightness of sealed building joints: Comparison of performance before and after artificial ageing. Building and Environment, 180, 107010. https://doi.org/10.1016/J.BUILDENV.2020.107010

    84.      Cheng, Z., Wong, J. K., & Mercan, O. (2025). Evaluating the wind loads on high-rise buildings of various plan dimensions through numerical simulations. Engineering Structures, 343, 120981. https://doi.org/10.1016/J.ENGSTRUCT.2025.120981

    85.      Singh, A., Kontoni, D.-P. N., & Mandal, S. (2024). CFD analysis of the impact of corner adjustments in tall square buildings for wind load mitigation. Engineering Research Express, 6(4), 045114. https://doi.org/10.1088/2631-8695/AD8B11

    86.      Juan, Y. H., Rezaeiha, A., Montazeri, H., Blocken, B., & Yang, A. S. (2024). Improvement of wind energy potential through building corner modifications in compact urban areas. Journal of Wind Engineering and Industrial Aerodynamics, 248. https://doi.org/10.1016/J.JWEIA.2024.105710

    87.      Jamińska-Gadomska, P., & Sumorek, A. (2025). Experimental Investigation of Local Wind Effects on Façade Scaffolding Structures. Applied Sciences, 15(22), 12196. https://doi.org/10.3390/APP152212196

    88.      Biler, A., Tavil, A. U., Su, Y., & Khan, N. (2018). A Review of Performance Specifications and Studies of Trickle Vents. Buildings, 8(11), 152. https://doi.org/10.3390/BUILDINGS8110152

    89.      Mokhov, I. I., & И., М. И. (2023). Russian Climate Research in 2019–2022. Izvestiya, Atmospheric and Oceanic Physics, 59(7), 830–851. https://doi.org/10.31857/S0002351523070106

    90.      Dobkowski, J., & Gajewski, A. (2025). Stack Ventilation Performance in a Semi-Detached House After Limiting Energy Consumption for Space Heating. Energies, 18(17), 4616. https://doi.org/10.3390/EN18174616

    91.      Bak, J., Koo, J., Yoon, S., & Lim, H. (2022). Thermal Draft Load Coefficient for Heating Load Differences Caused by Stack-Driven Infiltration by Floor in Multifamily High-Rise Buildings. Energies, 15(4), 1386. https://doi.org/10.3390/EN15041386

    92.      VEKA Softline 82. https://www.veka.ru/production/special/profilnye-sistemy-veka/veka-softline-82

     

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Предыдущая статья