Temperature of the inner surface of translucent structures. A Review

Строительные конструкции, здания и сооружения
Авторы:
Аннотация:

This review article provides a critical analysis of methods for assessing the temperature regime of the interior surfaces of translucent structures and substantiates the need to move from standardized methods to multiphysics modeling. The focus is on identifying factors influencing the formation of local temperature fields in translucent structures and analyzing inconsistencies in regulatory documents that affect the accuracy of condensation risk prediction. Methodology. A systematic analysis was conducted of scientific literature (publications from 2020 onwards, sourced from the Scopus database) and regulatory documents governing the thermal protection of building envelope components. Analysis of the methodology for calculating the internal surface temperature using regulatory formulas was provided, along with comparative engineering calculations for central and edge glazing zones with varying equivalent thermal resistance and heat-transfer coefficients. Results and Discussion. It has been shown that the temperature of the interior surfaces of translucent structures is influenced by a combination of factors, including localized «thermal bridges,» drafts, the geometry of structural junctions, and heating and ventilation regimes. Regulatory simplifications (average reduced resistance, fixed heat transfer coefficient of 8 W/ (m2 °C), use of «serviced zone» parameters) lead to significant discrepancies between calculated and actual conditions. Analytical calculations revealed significant temperature heterogeneity across the glazing area: edge and node zones (hinges, window sill abutments, bay window corners) regularly have lower temperatures than central sections. It was found that the total heat transfer coefficient on many internal surfaces often lies in the range of 3−5 W/ (m2 °C), rather than 8 W/ (m2 °C), which significantly impacts surface temperature predictions and the risk of condensation. It is noted that laboratory-determined values of reduced heat transfer resistance do not take into account the influence of pressure differences and wind loads that increase blowing in nature. Conclusion. To improve the accuracy of temperature field forecasts and reduce the risk of condensation, it is necessary to revise regulatory methodologies: consider the local distribution of heat transfer resistance and local heat exchange coefficients, incorporate the effects of infiltration and pressure drops, and determine microclimatic parameters near enclosing surfaces. A transition to multidimensional multiphysics modeling combined with full-scale testing and the development of practice-oriented calculation algorithms that take into account the design features of components and interactions with heating devices and shading devices is recommended. These measures will improve the reliability of energy assessments of translucent structures.

  • Список литературы

    1.        Nemova, D. V., Vasileva, I. L., & Vatin, N. I. (2019). Introduction of double-skin facades in the Russian Federation. Construction of Unique Buildings and Structures, 84(9), 51–62. https://doi.org/10.18720/CUBS.84.4

    2.        Luchkin, E. A., & Ivanchuk, E. V. (2021). Classification of translucent facade systems (in Rus). StudNet, 4(11), 1–13. https://cyberleninka.ru/article/n/klassifikatsiya-svetoprozrachnyh-fasadnyh-sistem

    3.        Abolghasemi Moghaddam, S., Simões, N., & Gameiro da Silva, M. (2023). Review of the experimental methods for evaluation of windows' solar heat gain coefficient: From standardized tests to new possibilities. Building and Environment, 242, 110527. https://doi.org/10.1016/J.BUILDENV.2023.110527

    4.        Pham, H., Soto, A., & Arul, M. (2025). Identification of features influencing glass façade damage in mid- to high-rise buildings during extreme wind events. Journal of Wind Engineering and Industrial Aerodynamics, 267, 106232. https://doi.org/10.1016/J.JWEIA.2025.106232

    5.        Panaritis, C., Couillard, M., Baranova -, E. A., Bukola, S., Mayura Silva, L., Creager, S. E., … Akhrorova, M. (2023). Improvement of the method of calculation of the reduced heat transfer resistance of light openings of buildings. Journal of Physics: Conference Series, 2573(1), 012045. https://doi.org/10.1088/1742-6596/2573/1/012045

    6.        Kamalisarvestani, M., Saidur, R., Mekhilef, S., & Javadi, F. S. (2013). Performance, materials and coating technologies of thermochromic thin films on smart windows. Renewable and Sustainable Energy Reviews, 26(26), 353–364. Retrieved from https://www.sciencedirect.com/science/article/pii/S1364032113003419

    7.        Moghaddam, S. A., Mattsson, M., Ameen, A., Akander, J., Gameiro Da Silva, M., & Simões, N. (2021). Low-Emissivity Window Films as an Energy Retrofit Option for a Historical Stone Building in Cold Climate. Energies, 14(22), 7584. https://doi.org/10.3390/EN14227584

    8.        Krarti, M. (2022). Performance of smart glazed overhang systems for US residential buildings. Building and Environment, 208, 108634. https://doi.org/10.1016/J.BUILDENV.2021.108634

    9.        Arici, M., Karabay, H., & Kan, M. (2015). Flow and heat transfer in double, triple and quadruple pane windows. Energy and Buildings, 86, 394–402. https://doi.org/10.1016/J.ENBUILD.2014.10.043

    10.      Vasileva, I. L., Nemova, D. V., Vatin, N. I., Fediuk, R. S., & Karelina, M. I. (2022). Climate-Adaptive Façades with an Air Chamber. Buildings, 12(3), 366. https://doi.org/10.3390/BUILDINGS12030366

    11.      Andreeva, D., Nemova, D., & Kotov, E. (2022). Multi-Skin Adaptive Ventilated Facade: A Review. Energies, 15(9), 3447. https://doi.org/10.3390/EN15093447

    12.      Ma'bdeh, S. N., Alali, R. O., Al-Shawabkeh, M., Almomani, R. M., Hamasha, A. A., Shannik, R., & Alrebei, O. F. (2025). Optimizing airflow in double-skin facades: Influence of vents design and cavity depth. Cleaner Engineering and Technology, 26, 100980. https://doi.org/10.1016/J.CLET.2025.100980

    13.      Zhao, X., Song, Y., Dong, Q., Huang, L., Wang, Y., & Shi, L. (2025). Solar radiation-controllable double-skin façades to enhance natural ventilation for green buildings. Renewable Energy, 255, 123805. https://doi.org/10.1016/J.RENENE.2025.123805

    14.      Nemova, D. V., Kotov, E. V., Daurov, Z. S., & Olshevskiy, V. I. (2020). Energy Efficiency of Closed Cavity Fasades. Construction of unique buildings and structures, 93(8), 9305–9305. https://doi.org/10.18720/CUBS.93.5

    15.      Tao, Y., Yan, Y., Tu, J., & Shi, L. (2024). Impact of wind on solar-induced natural ventilation through double-skin facade. Applied Energy, 364, 123205. https://doi.org/10.1016/J.APENERGY.2024.123205

    16.      Laczkó, A., & Nagy, B. (2026). Thermal Performance Modeling of Point-Fixed Glass Façades. Lecture Notes in Civil Engineering, 795 LNCE, 829–845. https://doi.org/10.1007/978-3-032-14011-1_66

    17.      Binyas, B. L., Sulaiman, M. K. A. M., Hembali, N. H., Rauf, A. A., Ayyash, A. B., & Wei, W. (2025). Application of Inclined Glass Wall as Building Facade under Tropical Climate Condition. Jurnal Kejuruteraan, 37(5), 2059–2070. https://doi.org/10.17576/jkukm-2025-37(5)-02

    18.      Imomova, N., Komilov, O., Majitov, J., Ergashov, J., & Usmonov, K. (2021). Calculation of the power of thermal energy consumed for heating the reactor of a bioenergy plant. E3S Web of Conferences, 264, 04069. https://doi.org/10.1051/E3SCONF/202126404069

    19.      Baygi, S. J. M. (2023). Effect of the Thin Silver Layer in SnO2/Ag/SnO2 Nano-Coatings with Low Emission for Energy Storage. Journal of Electronic Materials, 52(7), 4532–4539. https://doi.org/10.1007/S11664-023-10339-4

    20.      Zakharov, A. N., Kovsharov, N. F., Oskomov, K. V., Rabotkin, S. V., Solovyev, A. A., & Sochugov, N. S. (2012). Properties of low-emission coatings based on Ag and Cu deposited on polymer film by magnetron sputtering. Inorganic Materials: Applied Research, 3(5), 433–439. https://doi.org/10.1134/S2075113312050206

    21.      Ma, Y., Yang, D., Jiang, Q., Zhu, K., Yuan, H., Cui, J., & Yuan, L. (2020). TiN-based organic-inorganic composite films with dual functions of solar control and low-emission for energy-saving coatings. Materials Research Express, 7(6). https://doi.org/10.1088/2053-1591/ab96fd

    22.      Huang, Z., & Yang, E. (2025). Highly solar transparent and low-emissivity glass based on hydrogen-doped indium oxide. Materials Science and Engineering: B, 312, 117818. https://doi.org/10.1016/J.MSEB.2024.117818

    23.      Solovyev, A. A., Rabotkin, S. V., & Kovsharov, N. F. (2015). Polymer films with multilayer low-E coatings. Materials Science in Semiconductor Processing, 38, 373–380. https://doi.org/10.1016/j.mssp.2015.02.051

    24.      Gong, J., Wu, R., Hu, Y., Wang, S., & Mao, J. (2026). A multiple cross-linked photo-/thermo-dual-responsive hydrogel for energy-efficient smart windows with integrated UV monitoring and information encryption. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 748, 140969. https://doi.org/10.1016/J.COLSURFA.2026.140969

    25.      Zhao, Y., Ji, H., Lu, M., Tao, J., Ou, Y., Wang, Y., … Mao, Y. (2022). Thermochromic Smart Windows Assisted by Photothermal Nanomaterials. Nanomaterials, 12(21), 3865. https://doi.org/10.3390/NANO12213865

    26.      Zhang, K., Tai, X., Jiao, S., Zhang, Y., & Zou, Q. (2026). Temperature adaptive regulating window boosted by incorporating modified PNIPAM hydrogels with PVDF for building energy efficiency. Energy and Buildings, 354, 116993. https://doi.org/10.1016/J.ENBUILD.2026.116993

    27.      Raghuwanshi, V. S., Joram Mendoza, D., Browne, C., Ayurini, M., Gervinskas, G., Hooper, J. F., … Garnier, G. (2023). Effect of temperature on the conformation and functionality of poly(N-isopropylacrylamide) (PNIPAM)-grafted nanocellulose hydrogels. Journal of Colloid and Interface Science, 652, 1609–1619. https://doi.org/10.1016/J.JCIS.2023.08.152

    28.      Kotliarskaia, I. L., Nosova, A. O., Uspenskaya, M. V., & Vatin, N. I. (2025). Thermosensitive Coatings: A Review. AlfaBuild, 35(3), 3502–3502. https://doi.org/10.57728/ALF.35.2

    29.      Chen, X., Cui, J., Liu, Z., Wang, Y., Li, M., Zhang, J., … Wei, Q. (2024). Polyacrylamide/sodium alginate/sodium chloride photochromic hydrogel with high conductivity, anti-freezing property and fast response for information storage and electronic skin. International Journal of Biological Macromolecules, 268, 131972. https://doi.org/10.1016/J.IJBIOMAC.2024.131972

    30.      Castillo, S., Ramírez, Ó., Kortaberria, G., Forero-Giron, A. C., Cortés-Arriagada, D., Pizarro, N., … Leiva, Á. (2026). Transparent photoactive azobenzene-functionalized poly(ε-caprolactone)/chitosan nanofiber composites for solid-state molecular solar thermal energy storage. Reactive and Functional Polymers, 106857. https://doi.org/10.1016/J.REACTFUNCTPOLYM.2026.106857

    31.      Shao, Q., Yang, M., Wang, J., Wang, T., Wang, B., Fan, Y., & Wang, Y. (2026). Ultrasound/light/pH interactive control over cycling reconfiguration of spiropyran surfactant bowl-shaped nano-assemblies. Chinese Chemical Letters, 112647. https://doi.org/10.1016/J.CCLET.2026.112647

    32.      Li, Z., Zheng, W., Ji, R., Zhao, Y., Wang, K. P., Chen, S., & Hu, Z. Q. (2026). Multistimuli responsive fluorescent materials based on unsymmetric diarylvinyl anthracene-type solid-state fluorophores. Dyes and Pigments, 246, 113402. https://doi.org/10.1016/J.DYEPIG.2025.113402

    33.      Zuo, W., Chen, Q., Xie, Z., Habib, S., Jing, Y., Zhang, X., … Zhu, J. (2023). Synthesis of sodium alginate/polyacrylamide photochromic hydrogels with quadruple crosslinked networks. Journal of Materials Chemistry B, 11(29), 6952–6960. https://doi.org/10.1039/D3TB00141E

    34.      Usha, K. S., Vijaya Prasath, G., & Lee, S. Y. (2026). Nickel–tungsten oxide thin films: Enhanced switching kinetics via thermal treatment for energy-efficient smart window applications. Ceramics International, 52(8), 10671–10680. https://doi.org/10.1016/J.CERAMINT.2026.01.243

    35.      Bhattacharjee, S., Pramanik, J., Das, A., Ghosh, S., & Kundu, S. (2026). Time resolved phase engineering of sub-stoichiometric tungsten oxide for advanced electrochromic smart windows. Materials Today Chemistry, 54, 103696. https://doi.org/10.1016/J.MTCHEM.2026.103696

    36.      Abouelleef, E. M., Wahba, R. H., El-Sonbati, A. Z., Diab, M. A., & Gomaa, E. A. (2026). Electrochemical, thermodynamic, and antibacterial evaluation of ammonium molybdate in acidic medium with eosin yellow: Cyclic voltammetry. Journal of Molecular Liquids, 442, 129114. https://doi.org/10.1016/J.MOLLIQ.2025.129114

    37.      Moon, C. W., Bhoumik, N. C., Mondol, P., Park, S. H., Jang, H. W., & Barile, C. J. (2023). Origin of high optical contrast in zinc-zinc oxide electrodeposits for dynamic windows. Nano Energy, 114, 108666. https://doi.org/10.1016/J.NANOEN.2023.108666

    38.      Skandalos, N., & Karamanis, D. (2015). PV glazing technologies. Renewable and Sustainable Energy Reviews, 49, 306–322. https://doi.org/10.1016/J.RSER.2015.04.145

    39.      Norton, B., Eames, P. C., Mallick, T. K., Huang, M. J., McCormack, S. J., Mondol, J. D., & Yohanis, Y. G. (2011). Enhancing the performance of building integrated photovoltaics. Solar Energy, 85(8), 1629–1664. https://doi.org/10.1016/J.SOLENER.2009.10.004

    40.      Wang, M., Peng, J., Li, N., Yang, H., Wang, C., Li, X., & Lu, T. (2017). Comparison of energy performance between PV double skin facades and PV insulating glass units. Applied Energy, 194, 148–160. https://doi.org/10.1016/J.APENERGY.2017.03.019

    41.      Wang, K., Yang, X., Yan, D., Liu, T., Liu, L., & Zhang, W. (2026). Dual-Salt Hydrogel Electrolyte for a Robust Zn-Ion Electrochromic Device toward Dynamic Infrared Regulation. ACS Applied Materials & Interfaces, 18(15), 22171–22183. https://doi.org/10.1021/ACSAMI.6C02668

    42.      Yan, D., Liu, L., Guo, T., Zhang, Z., Wang, M., Li, C., … Hu, S. (2025). High-performance reflective-type Zn-ions electrochromic devices toward visible-to-infrared broadband dynamic regulation. Chemical Engineering Journal, 504, 159117. https://doi.org/10.1016/J.CEJ.2024.159117

    43.      Niknia, S., & Rashed-Ali, H. (2024). Analyzing energy consumption due to occupant interaction with manual and automatic window blinds in multiple climates. Journal of Building Engineering, 90, 109506. https://doi.org/10.1016/J.JOBE.2024.109506

    44.      Nilsson, A. M., & Jonsson, J. C. (2010). Light-scattering properties of a Venetian blind slat used for daylighting applications. Solar Energy, 84(12), 2103–2111. https://doi.org/10.1016/J.SOLENER.2010.09.005

    45.      Chaiyapinunt, S., & Worasinchai, S. (2009). Development of a mathematical model for a curved slat venetian blind with thickness. Solar Energy, 83(7), 1093–1113. https://doi.org/10.1016/J.SOLENER.2009.01.013

    46.      Al-Obaidi, K. M., Ismail, M. A., & Abdul Rahman, A. M. (2015). Assessing the allowable daylight illuminance from skylights in single-storey buildings in Malaysia: a review. International Journal of Sustainable Building Technology and Urban Development, 6(4), 236–248. https://doi.org/10.1080/2093761X.2015.1129369

    47.      Al-Masrani, S. M., & Al-Obaidi, K. M. (2019). Dynamic shading systems: A review of design parameters, platforms and evaluation strategies. Automation in Construction, 102, 195–216. https://doi.org/10.1016/J.AUTCON.2019.01.014

    48.      Eames, P. C. (2008). Vacuum glazing: Current performance and future prospects. Vacuum, 82(7), 717–722. https://doi.org/10.1016/J.VACUUM.2007.10.017

    49.      Bi, Q., Jin, Q., Cao, M., & Yu, Z. (2026). Investigation of the Photothermal–Electrical Characteristics of Insulated and Ventilated Photovoltaic Vacuum Glazing Systems. Renewable Energy, 126110. https://doi.org/10.1016/J.RENENE.2026.126110

    50.      Mi, W., Pu, J., Shen, C., Chen, G., & Soteris, K. A. (2025). Vacuum-structured electrochromic glazing windows with ultra-low U-Values for building energy savings in all climatic zones. Energy, 336, 138496. https://doi.org/10.1016/J.ENERGY.2025.138496

    51.      Buratti, C., Belloni, E., Merli, F., & Zinzi, M. (2021). Aerogel glazing systems for building applications: A review. Energy and Buildings, 231, 110587. https://doi.org/10.1016/J.ENBUILD.2020.110587

    52.      Zheng, D., Chen, Y., & Yan, D. (2025). Effects of optical scattering in aerogel glazing system on daylight illuminance and discomfort glare. Building and Environment, 286, 113765. https://doi.org/10.1016/J.BUILDENV.2025.113765

    53.      Gao, T., Jelle, B. P., Ihara, T., & Gustavsen, A. (2014). Insulating glazing units with silica aerogel granules: The impact of particle size. Applied Energy, 128, 27–34. https://doi.org/10.1016/J.APENERGY.2014.04.037

    54.      Liu, Y., Wang, Y., Wang, X., Xu, Y., Li, X., Liu, Y., … Wu, X. H. (2025). Investigation on the optical, thermal, and electrical performance of photovoltaic-aerogel glazing system under different weather conditions. Energy, 326, 136335. https://doi.org/10.1016/J.ENERGY.2025.136335

    55.      Belloni, E., Anderson, A. M., Carroll, M. K., Frizzi, B., Pierini, T., & Buratti, C. (2026). Innovative glazing systems composed of photovoltaic cells and monolithic aerogel layers: Electrical and thermal experimental characterization and simulation analysis. Energy and Buildings, 356, 117071. https://doi.org/10.1016/J.ENBUILD.2026.117071

    56.      Vukadinović, A., Radosavljević, J., & Đorđević, A. (2020). Energy performance impact of using phase-change materials in thermal storage walls of detached residential buildings with a sunspace. Solar Energy, 206, 228–244. https://doi.org/10.1016/J.SOLENER.2020.06.008

    57.      Liu, C., Zheng, Y., Li, D., Qi, H., & Liu, X. (2016). A Model to Determine Thermal Performance of a Non-ventilated Double Glazing Unit with PCM and Experimental Validation. Procedia Engineering, 157, 293–300. https://doi.org/10.1016/J.PROENG.2016.08.369

    58.      Yan, W., Sang, G., Cai, P., Zhang, X., Cui, X., Ban, T., & Shen, M. (2026). Light-transmitting and energy-storing integrated PEG-HPMC phase change film for transparent building envelopes: Preparation, properties, and thermal regulation simulation. Energy and Built Environment. https://doi.org/10.1016/J.ENBENV.2026.06.003

    59.      Čekon, M., Slávik, R., Čurpek, J., Cottone, R., & Bevilacqua, P. (2025). An integrated adaptive façade system using a glass block filled with phase change material: Cooling energy load and performance enhancement. Building and Environment, 273, 112724. https://doi.org/10.1016/J.BUILDENV.2025.112724

    60.      Ceviz, M. A., Mandev, E., Muratçobanoğlu, B., Çelik, A., & Afshari, F. (2023). Experimental analysis of energy storage performance of phase change materials in horizontal double-glazing applications. Journal of Energy Storage, 73, 108836. https://doi.org/10.1016/J.EST.2023.108836

    61.      Çelik, A., Mandev, E., Ersan, O., Muratçobanoğlu, B., Ceviz, M. A., & Kara, Y. A. (2025). Thermal performance evaluation of PCM-integrated interior shading devices in building glass facades. Journal of Energy Storage, 113, 115614. https://doi.org/10.1016/J.EST.2025.115614

    62.      Gonçalves, M., Figueiredo, A., Almeida, R. M. S. F., & Vicente, R. (2025). Design and thermal performance analysis of a dynamic shading device incorporating phase change materials. Journal of Energy Storage, 134, 118179. https://doi.org/10.1016/J.EST.2025.118179

    63.      Öztürk, B., Mutlu-Avinç, G., & Arslan-Selçuk, S. (2024). Enhancing energy efficiency in glass facades through biomimetic design strategies. Revista Hábitat Sustentable, 14(1), 34–43. https://doi.org/10.22320/07190700.2024.14.01.03

    64.      Sommese, F., Hosseini, S. M., Badarnah, L., Capozzi, F., Giordano, S., Ambrogi, V., & Ausiello, G. (2024). Light-responsive kinetic façade system inspired by the Gazania flower: A biomimetic approach in parametric design for daylighting. Building and Environment, 247, 111052. https://doi.org/10.1016/J.BUILDENV.2023.111052

    65.      Sommese, F., Badarnah, L., & Ausiello, G. (2022). A critical review of biomimetic building envelopes: towards a bio-adaptive model from nature to architecture. Renewable and Sustainable Energy Reviews, 169, 112850. https://doi.org/10.1016/J.RSER.2022.112850

    66.      Yessengabulov, S., Kozhakhmet, M., Zharkenov, Y., Abakanov, Y., Dastenova, G., Nurbayeva, M., … Jexembayeva, A. (2025). Study of the Possibility of Transition to More Stringent Energy Efficiency Requirements for Translucent Structures in the Republic of Kazakhstan. Buildings, 15(13), 2354. https://doi.org/10.3390/BUILDINGS15132354/S1

    67.      SP 50.13330.2024 Thermal performance of the buildings. https://meganorm.ru/mega_doc/norm/pasport_forma/0/sp_50_13330_2024_svod_pravil_teplovaya_zashchita_zdaniy.html

    68.      Moed, H. F., Bar-Ilan, J., & Halevi, G. (2016). A new methodology for comparing Google Scholar and Scopus. Journal of Informetrics, 10(2), 533–551. https://doi.org/10.1016/J.JOI.2016.04.017

    69.      Montoya, F. G., Alcayde, A., Baños, R., & Manzano-Agugliaro, F. (2018). A fast method for identifying worldwide scientific collaborations using the Scopus database. Telematics and Informatics, 35(1), 168–185. https://doi.org/10.1016/J.TELE.2017.10.010

    70.      SP 538.1325800.2024 Window and balcony constructions. Design rules. https://docs.cntd.ru/document/1306394702

    71.      Pirozhnikova, A. P., Bukarov, N. V., & Vasilenko, V. V. (2019). To the question of improving the regulatory framework for energy efficiency of buildings and structures within SP 50.13330.2012 "Thermal protection of buildings," 8(59), 34. https://elibrary.ru/item.asp?id=42406135

    72.      Perekhozhentsev, A. G. (2018). Norming and Calculation of Vapor Permeability of MultiLayer Building Enclosing Structures (Recommendations for Improving SP 50.13330.2012 "Thermal Protection of Buildings"). Scientific journal "ACADEMIA. ARCHITECTURE AND CONSTRUCTION," (3), 130–134. https://doi.org/10.22337/2077-9038-2018-3-130-134

    73.      Bodrov, M. V., Yulanova, A. F., & Ruin, A. E. (2024). Scientific and methodological justification of theneed to amend SP 50.13330.2012 "SNIP 23022003 Thermal protection of buildings." Privolzhsky Scientific Journal, 1(69), 49–54. Retrieved from https://elibrary.ru/item.asp?id=65395525

    74.      Nie, J., & Liu, X. (2024). A review of dew point sensors: Recent advances and future development. Sensors and Actuators B: Chemical, 417, 136115. https://doi.org/10.1016/J.SNB.2024.136115

    75.      SP 131.13330.2025 Building climatology.https://docs.cntd.ru/document/1313808224

    76.      Lawrence, M. G. (2005). The relationship between relative humidity and the dewpoint temperature in moist air: A simple conversion and applications. Bulletin of the American Meteorological Society, 86(2), 225–233. https://doi.org/10.1175/BAMS-86-2-225

    77.      GOST 30494-2011 "Residential and public buildings. Microclimate parameters for indoor enclosures." (n.d.). Retrieved May 21, 2026, from https://docs.cntd.ru/document/1200095053

    78.      Komatsu, T., & Honma, T. (2026). A comprehensive revisit to "what is glass" from nanoscale heterogeneous structure. Journal of Solid State Chemistry, 361, 126072. https://doi.org/10.1016/J.JSSC.2026.126072

    79.      Konstantinov, A. P., Aksenov, I. S., & Elohov, A. E. (2023). The use of Thermography to Determine the Boundary Conditions of Heat Exchange on The Inner Surfaces of Translucent Enclosing Structures. Zhilishchnoe Stroitel'stvo, 18–21. https://doi.org/10.31659/0044-4472-2023-12-18-21

    80.      Collins, M. (2004). Convective heat transfer coefficients from an internal window surface and adjacent sunlit Venetian blind. Energy and Buildings, 36(3), 309–318. https://doi.org/10.1016/J.ENBUILD.2003.12.014

    81.      Song, S., Chen, Y., Long, J., & Wang, P. (2026). A curtain regulating strategy for high energy performance in office buildings. Renewable Energy, 265, 125642. https://doi.org/10.1016/J.RENENE.2026.125642

    82.      Merve Bulut, Merve Kucukali Ozturk, Cevza Candan, Banu Nergis, Tuğba Zengin, Aysun Yenice, … Ecenur Tor. (2022). Evaluation of light blocking effect and acoustic performance of blackout fabrics. In Conference: 4th International Eurasian Conference on Science, Engineering and Technology (EurasianSciEnTech 2022) At: Ankara, Turkey. https://www.researchgate.net/publication/366324830_Evaluation_of_light_blocking_effect_and_acoustic_performance_of_blackout_fabrics

    83.      Shi, Y., & Li, X. (2020). Effect of mechanical ventilation on infiltration rate under stack effect in buildings with multilayer windows. Building and Environment, 170, 106594. https://doi.org/10.1016/J.BUILDENV.2019.106594

    84.      Rogal, I. O. (2024). Calculating the stack effect in high-rise buildings and how it affects ventilation systems (in rus). Current research (in rus), (22 (204)). https://apni.ru/article/9440-raschet-stak-effekta-v-vysotnyh-zdaniyah-i-kak-on-vliyaet-na-sistemy-ventilyacii

    85.      Qin, X., Liu, H., Zhang, X., Jiang, N., Yang, L., & Jin, X. (2024). Thermal analysis of the window-wall interface for renovation of historical buildings. Energy and Buildings, 310, 114108. https://doi.org/10.1016/J.ENBUILD.2024.114108

    86.      Xie, C., Yang, Y., Li, Q., Yu, X., Wang, Z., Bai, B., … Guo, Y. (2026). Accessing the stack effect in high-rise buildings by the probability method based on climate demarcation: A case study in China. Energy and Built Environment, 7(3), 519–533. https://doi.org/10.1016/J.ENBENV.2025.01.002

    87.      Hirvonen, E., Katsura, T., & Nagano, K. (2024). Further Experiments in Integrating Transparent Photovoltaic Film with Transparent Vacuum Insulation Panel. 2024 11th International Conference on Power and Energy Systems Engineering, CPESE 2024, 280–284. https://doi.org/10.1109/CPESE62584.2024.10840706

    88.      Parfenov, G. I., Smirnov, N. N., & Tyutikov, V. V. (2024). Energy Efficiency of Using Heat-Reflecting Screens with Solar Photovoltaic Panels in Windows. Proceedings - 2024 International Conference on Industrial Engineering, Applications and Manufacturing, ICIEAM 2024, 250–254. https://doi.org/10.1109/ICIEAM60818.2024.10554005

    89.      Paneru, S., Wang, J., Elmi, M., Chi, G., & Hu, Y. (2025). Envelope impact on indoor thermal resilience across different housing types during extreme heatwaves and power outages. Journal of Building Engineering, 115, 114516. https://doi.org/10.1016/J.JOBE.2025.114516

    90.      SP 60.13330.2020Heating, ventilation and air conditioning. https://docs.cntd.ru/document/573697256

    91.      Wang, M., Li, P., & Liu, W. (2022). Generic mathematical formulation of the total heat transfer coefficients between heated radiant floor surfaces and rooms. Building and Environment, 211, 108701. https://doi.org/10.1016/J.BUILDENV.2021.108701

    92.      Bellagh, L., Merabtine, A., Kheiri, A., Mokraoui, S., & Kauffmann, J. (2021). Studies on how to counteract overheating caused by sun patch exposure in ventilated highly glazed spaces heated by floor heating systems. Solar Energy, 220, 991–1005. https://doi.org/10.1016/J.SOLENER.2021.04.008

    93.      Duan, Q., Hinkle, L., Wang, J., Zhang, E., & Memari, A. (2021). Condensation effects on energy performance of building window systems. Energy Reports, 7, 7345–7357. https://doi.org/10.1016/J.EGYR.2021.10.096

    94.      Laukkarinen, A., Kero, P., & Vinha, J. (2018). Condensation at the exterior surface of windows. Journal of Building Engineering, 19, 592–601. https://doi.org/10.1016/J.JOBE.2018.06.014

     

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Предыдущая статьяСледующая статья