      <title-group>
        <article-title>Double skin facade with ventilated buffer zone</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Двойные фасады с вентилируемыми буферными зонами</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Kuritsyn</surname>
            <given-names>Aleksey Olegovych</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>alekurn@gmail.com</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Pavlova</surname>
            <given-names>Natalia Yuryevna</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>pavlowa.natalia@gmail.com</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Opanasenko</surname>
            <given-names>Ilya Aleksandrovich</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>89215696811@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Bolotovskiy</surname>
            <given-names>Vladislav Vladimirovich</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>vladslavb@gmail.com</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Andreeva</surname>
            <given-names>Darya Sergeevna</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>tarasovads@gmail.com</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russian Federation</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2018-05-01">
        <day>01</day>
        <month>05</month>
        <year>2018</year>
      </pub-date>
      <volume>7</volume>
      <issue>5</issue>
      <issue-id pub-id-type="publisher-id">7</issue-id>
      <fpage>47</fpage>
      <lpage>58</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://alfabuild.spbstu.ru/userfiles/files/AlfaBuild/AlfaBuild_2018_7/7_5-1.pdf"/>
      <abstract xml:lang="en">
        <p>This article is focused to analysis of actual publicly-known characteristics of double-skin facades. The goal of work is to systematize the information about ventilated facade system and to create classification of double-skin facades by several parameters such as noise isolation, fire protection, scheme of air course, light transmission capacity, convenience of maintenance and some climatic factors. In addition in article were examined a number of parameters of ventilation systems. importance of such research is confirmed by increase in distribution ventilated facade systems in construction and requirement of requirement of definition economically and practically favorable types of facades. As result was made a comparative analysis of facades for various types of filling the internal space by main technical characteristics and by efficiency of use in various climatic conditions. Finally, facades were ranged and was determined the best type – facade with ventilated double window partitioning</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Double-skin facade</kwd>
        <kwd>thermal performance</kwd>
        <kwd>energy efficiency</kwd>
        <kwd>heat transfer analysis</kwd>
        <kwd>energy consumption</kwd>
        <kwd>natural ventilation</kwd>
        <kwd>passive cooling</kwd>
        <kwd>integrated design</kwd>
      </kwd-group>